ANALISIS RISIKO PAJANAN POLUSI UDARA DALAM RUANG TERHADAP KAPASITAS VITAL PARU PADA PETUGAS LABORATORIUM DI UNIVERSITAS SRIWIJAYA

WIDIYARISTI, DESSY and Sunarsih, Elvi and Flora, Rostika (2023) ANALISIS RISIKO PAJANAN POLUSI UDARA DALAM RUANG TERHADAP KAPASITAS VITAL PARU PADA PETUGAS LABORATORIUM DI UNIVERSITAS SRIWIJAYA. Masters thesis, Sriwijaya University.

[thumbnail of RAMA_13101_10012682226019.pdf] Text
RAMA_13101_10012682226019.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (4MB) | Request a copy
[thumbnail of RAMA_13101_10012682226019_TURNITIN.pdf] Text
RAMA_13101_10012682226019_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (14MB) | Request a copy
[thumbnail of RAMA_13101_10012682226019_0028067806_0227097101_01_front_ref.pdf] Text
RAMA_13101_10012682226019_0028067806_0227097101_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (1MB)
[thumbnail of RAMA_13101_10012682226019_0028067806_0227097101_02.pdf] Text
RAMA_13101_10012682226019_0028067806_0227097101_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (976kB) | Request a copy
[thumbnail of RAMA_13101_10012682226019_0028067806_0227097101_03.pdf] Text
RAMA_13101_10012682226019_0028067806_0227097101_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (526kB) | Request a copy
[thumbnail of RAMA_13101_10012682226019_0028067806_0227097101_04.pdf] Text
RAMA_13101_10012682226019_0028067806_0227097101_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (991kB) | Request a copy
[thumbnail of RAMA_13101_10012682226019_0028067806_0227097101_05.pdf] Text
RAMA_13101_10012682226019_0028067806_0227097101_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (240kB) | Request a copy
[thumbnail of RAMA_13101_10012682226019_0028067806_0227097101_06_ref.pdf] Text
RAMA_13101_10012682226019_0028067806_0227097101_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (254kB) | Request a copy
[thumbnail of RAMA_13101_10012682226019_0028067806_0227097101_07_lamp.pdf] Text
RAMA_13101_10012682226019_0028067806_0227097101_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy

Abstract

Laboratory workers are a group that is vulnerable to exposure to air pollution in the form of gas and dust in the room so that it has an impact on health. One of them is laboratory workers at Sriwijaya University who spend almost 90% of their time in the laboratory room during work shifts. The purpose of the study is to analyze the risks of the health of officers and the factors that have the most influence on lung capacity. The type of research is analytical research with cross-sectional method using Environmental Health Risk Analysis (EHR) approach. The research sample consisted of 51 laboratory officers measuring exposure in 30 laboratory rooms at Sriwijaya University. The results of the risk level (RQ) calculation showed the RQ value <1 for TSP exposure and PM2.5 dust is categorized as safe while the RQ value ≥1 for CO and CO2 exposure is categorized as unsafe. The univariate results showed that officers who experienced lung disorders were 82.4%. Bivariate results showed there was a correlation between the use of PPE (p=0.060) and exercise habits (p=0.002) with the vital lung capacity of Sriwijaya University laboratory officers. The results of the calculation of the risk level (RQ) obtained the RQ value <1 for TSP exposure and PM2.5 dust is categorized as safe while the RQ value ≥1 for CO and CO2 exposure is categorized as unsafe. The univariate results showed that officers who experienced lung disorders were 82.4%. Bivariate results showed there was a correlation between the use of PPE (p=0.060) and exercise habits (p=0.002) with the vital lung capacity of Sriwijaya University laboratory staff. The dominant factor affecting lung vital capacity is exercise habits with OR =14,930 (CI 1,587 – 140,433). In this study, risk management and risk management strategies are needed to reduce the concentration of air pollution exposure in the laboratory.

Item Type: Thesis (Masters)
Uncontrolled Keywords: Analisis Risiko Kesehatan Lingkungan, Polusi Udara Dalam Ruang, Petugas Laboratorium, CO, CO2, TSP, PM2,5
Subjects: R Medicine > RA Public aspects of medicine > RA428-428.5 Public health laboratories, institutes, etc.
R Medicine > RA Public aspects of medicine > RA565-600 Environmental health. Including sewage disposal, air pollution, nuisances,
T Technology > TD Environmental technology. Sanitary engineering > TD878-894 Special types of environment Including soil pollution, air pollution, noise pollution
Divisions: 10-Faculty of Public Health > 13101-Public Health Science (S2)
Depositing User: Dessy Widiyaristi
Date Deposited: 21 Jan 2025 01:33
Last Modified: 21 Jan 2025 01:33
URI: http://repository.unsri.ac.id/id/eprint/165196

Actions (login required)