VERIFIKASI METODE UJI ANALISIS ULTIMAT BATU BARA MENGGUNAKAN ASTM D5373-21

FARADILA, DIA and Suheryanto, Suheryanto (2025) VERIFIKASI METODE UJI ANALISIS ULTIMAT BATU BARA MENGGUNAKAN ASTM D5373-21. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_47201_08031382126104_cover.jpeg]
Preview
Image
RAMA_47201_08031382126104_cover.jpeg - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (399kB) | Preview
[thumbnail of RAMA_47201_08031382126104.pdf] Text
RAMA_47201_08031382126104.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Request a copy
[thumbnail of RAMA_47201_08031382126104_TURNITIN.pdf] Text
RAMA_47201_08031382126104_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Request a copy
[thumbnail of RAMA_47201_08031382126104_0025066004_01_front_ref.pdf] Text
RAMA_47201_08031382126104_0025066004_01_front_ref.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy
[thumbnail of RAMA_47201_08031382126104_0025066004_02.pdf] Text
RAMA_47201_08031382126104_0025066004_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (644kB) | Request a copy
[thumbnail of RAMA_47201_08031382126104_0025066004_03.pdf] Text
RAMA_47201_08031382126104_0025066004_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (673kB) | Request a copy
[thumbnail of RAMA_47201_08031382126104_0025066004_04.pdf] Text
RAMA_47201_08031382126104_0025066004_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (544kB) | Request a copy
[thumbnail of RAMA_47201_08031382126104_0025066004_05.pdf] Text
RAMA_47201_08031382126104_0025066004_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (373kB) | Request a copy
[thumbnail of RAMA_47201_08031382126104_0025066004_06_ref.pdf] Text
RAMA_47201_08031382126104_0025066004_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (417kB) | Request a copy
[thumbnail of RAMA_47201_08031382126104_0025066004_07_lamp.pdf] Text
RAMA_47201_08031382126104_0025066004_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (7MB) | Request a copy

Abstract

This study was conducted to determine the precision and accuracy of the verification of the coal ultimate analysis test method. Coal samples that are still in the form of lumps are ground in stages using a jaw crusher to a size of 10 mm, a hammer mill to a size of 2.8 mm and a cross beater mill to a size of ±0.212 mm, then a fine coal powder is obtained that is ready to be tested. The method used is ASTM D5373-21 and the tool used is CHN Analyzer. Precision is determined by calculating the repeatability value and accuracy by calculating the bias value and percentage of bias from CRM (Certified Reference Material) testing using LECO CRM 502-680. The results of the study showed that the precision of the test method for the Standard Deviation (SD) values obtained were 0.17%; 0.02%; 0.01%, the experimental Coefficient of Variation (CV) values were obtained respectively at 0.24%; 0.46%; 1.67%, the Horwitz Coefficient of Variation (CV) values obtained were respectively 2.11%; 3.05%; 4%, and the 2/3 Horwitz Coefficient of Variation (CV) values obtained were respectively 1.41%; 2.04%; 2.68%. The results of the analysis of the determination of accuracy for the bias value were respectively 0.01%; 0.09% and 0.08% and the percentage bias values were respectively -0.02%; 2.25% and 6.68%. Based on this study, the verification of the coal ultimate analysis test method using ASTM D5373-21 was proven presicion and acurate.

Item Type: Thesis (Undergraduate)
Subjects: Q Science > QD Chemistry > QD71-142 Analytical chemistry
Divisions: 08-Faculty of Mathematics and Natural Science > 47201-Chemistry (S1)
Depositing User: Dia Faradila
Date Deposited: 18 Mar 2025 07:20
Last Modified: 18 Mar 2025 07:20
URI: http://repository.unsri.ac.id/id/eprint/169239

Actions (login required)

View Item View Item