ANALISA KEANDALAN SISTEM DISTRIBUSI KETENAGALISTRIKAN 20 KV DENGAN PENAMBAHAN RECLOSER DAN SECTIONALIZER PADA PENYULANG BEO DI GARDU INDUK SEDUDUK PUTIH DENGAN METODE FAILURE MODE EFFECT ANALYSIS (FMEA) DAN SOFTWARE ETAP 19.0.1

EDRIANI, SYABITAH PUTRI and Adipradana, Wirawan (2025) ANALISA KEANDALAN SISTEM DISTRIBUSI KETENAGALISTRIKAN 20 KV DENGAN PENAMBAHAN RECLOSER DAN SECTIONALIZER PADA PENYULANG BEO DI GARDU INDUK SEDUDUK PUTIH DENGAN METODE FAILURE MODE EFFECT ANALYSIS (FMEA) DAN SOFTWARE ETAP 19.0.1. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_20201_03041282126085_cover.jpg]
Preview
Image
RAMA_20201_03041282126085_cover.jpg - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (303kB) | Preview
[thumbnail of RAMA_20201_03041282126085.pdf] Text
RAMA_20201_03041282126085.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (12MB) | Request a copy
[thumbnail of RAMA_20201_03041282126085_TURNITIN.pdf] Text
RAMA_20201_03041282126085_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (6MB) | Request a copy
[thumbnail of RAMA_20201_03041282126085_0012018605_01_front_ref.pdf] Text
RAMA_20201_03041282126085_0012018605_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (1MB)
[thumbnail of RAMA_20201_03041282126085_0012018605_02.pdf] Text
RAMA_20201_03041282126085_0012018605_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy
[thumbnail of RAMA_20201_03041282126085_0012018605_03.pdf] Text
RAMA_20201_03041282126085_0012018605_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (845kB) | Request a copy
[thumbnail of RAMA_20201_03041282126085_0012018605_04.pdf] Text
RAMA_20201_03041282126085_0012018605_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy
[thumbnail of RAMA_20201_03041282126085_0012018605_05.pdf] Text
RAMA_20201_03041282126085_0012018605_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (241kB) | Request a copy
[thumbnail of RAMA_20201_03041282126085_0012018605_06_ref.pdf] Text
RAMA_20201_03041282126085_0012018605_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (220kB) | Request a copy
[thumbnail of RAMA_20201_03041282126085_0012018605_07_lamp.pdf] Text
RAMA_20201_03041282126085_0012018605_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (8MB) | Request a copy

Abstract

In the current era of electrification, the continuity of electricity distribution from power generation to consumers has become crucial. The reliability of the distribution system at the feeder level serves as an important indicator in assessing the quality of service provided by electricity suppliers. This study aims to analyze the reliability of the Beo Feeder at the Seduduk Putih Substation using the Failure Mode Effect Analysis (FMEA) method and simulation with ETAP 19.0.1 software, as well as to determine the impact of adding a recloser and a combination of recloser and sectionalizer on the feeder through a reliability assessment simulation in ETAP 19.0.1. The reliability indices analyzed include SAIFI, SAIDI, and CAIDI, which are compared to the SPLN 2011 and IEEE P1366-2003 standards to determine whether the feeder is classified as reliable or unreliable. The analysis results show that under existing conditions, the SAIFI, SAIDI, and CAIDI values using the FMEA method are 1,387260; 2,338064; and 1,681523, respectively. Meanwhile, the simulation using ETAP software produced SAIFI, SAIDI, and CAIDI values of 1,5633; 2,7800; and 1,7778,respectively. After the addition of a recloser, the values became 1,3029; 2,6512; and 2,035, respectively. Furthermore, with the addition of both a recloser and sectionalizer, the values improved to 1,1117; 2,3410; and 2,106. These results indicate that the Beo Feeder is categorized as an unreliable feeder and that the addition of protection devices can improve the reliability of the distribution system.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Keandalan Sistem Distribusi, Penyulang Beo, Metode FMEA, ETAP 19.0.1, SAIFI, SAIDI, CAIDI, Recloser, Sectionalizer
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3001-3521 Distribution or transmission of electric power
Divisions: 03-Faculty of Engineering > 20201-Electrical Engineering (S1)
Depositing User: Syabitah Putri Edriani
Date Deposited: 23 Jun 2025 02:59
Last Modified: 23 Jun 2025 02:59
URI: http://repository.unsri.ac.id/id/eprint/175851

Actions (login required)

View Item View Item