RAMLI, AZMITHA NORA and Herlina, Herlina (2025) EVALUASI DAN PERANCANGAN MITIGASI NILAI HARMONIK PADA SISTEM KELISTRIKAN GEDUNG PT.PLN NUSANTARA POWER MUARA KARANG. Undergraduate thesis, Sriwijaya University.
![]() ![]() Preview |
Image
RAMA_20201_03041282126037_cover.jpg - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (296kB) | Preview |
![]() |
Text
RAMA_20201_03041282126037.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (20MB) | Request a copy |
![]() |
Text
RAMA_20201_03041282126037_TURNITIN.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (7MB) | Request a copy |
![]() |
Text
RAMA_20201_03041282126037_0007078005_01_front_ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (16MB) |
![]() |
Text
RAMA_20201_03041282126037_0007078005_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (472kB) | Request a copy |
![]() |
Text
RAMA_20201_03041282126037_0007078005_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) | Request a copy |
![]() |
Text
RAMA_20201_03041282126037_0007078005_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (857kB) | Request a copy |
![]() |
Text
RAMA_20201_03041282126037_0007078005_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (364kB) | Request a copy |
![]() |
Text
RAMA_20201_03041282126037_0007078005_06_ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (78kB) | Request a copy |
![]() |
Text
RAMA_20201_03041282126037_0007078005_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) | Request a copy |
Abstract
The quality of electrical power in the distribution system can be disturbed by harmonics, especially in installations with non-linear electronic equipment. This study was conducted at the PLN NP UP Muara Karang Building which uses loads such as LED lights and various electronic devices such as computers, laptops, printers, etc. that have the potential to produce harmonics. Initial measurement results showed that the THDi value reached 43.56%, exceeding the IEEE 519-2014 standard limit. System modeling and analysis were carried out using ETAP 19.0.1 software. To reduce harmonics, a passive filter was designed that focused on dominant order harmonics. Simulation results showed that after installing the filter, THDi decreased to 21.21% and THDv to 1.39%. In addition, the current decreased by around ±13 A, reactive power and apparent power also decreased, active power did not change significantly because it was not directly affected by harmonics. The system voltage increased by an average of ±0.30%, and the power factor improved to around 99%. This proves that harmonic mitigation can improve the quality of the power distribution system.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Harmonics, THDi, THDv, mitigation, IEEE Std 519-2014, ETAP 19.0.1 |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3001-3521 Distribution or transmission of electric power |
Divisions: | 03-Faculty of Engineering > 20201-Electrical Engineering (S1) |