BR.BUTAR BUTAR, WASNI THERESIA and Novrikasari, Novrikasari (2019) FAKTOR DETERMINAN KAPASITAS VITAL PARU PADA PEKERJA DI AREA PENGANTONGAN DAN PENYIMPANAN PUPUK UREA (PPU) PT.PUPUK SRIWIDJAJA PALEMBANG. Undergraduate thesis, Sriwjaya University.
![]() |
Text
A. RAMA_13201_10011181520069-converted.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) | Request a copy |
![]() |
Text
B. RAMA_13201_10011181520069 - Turnitin-converted.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) | Request a copy |
Preview |
Text
C. RAMA_13201_10011181520069_00211117801_01_front_ref Coverjudul, halaman pengesahan, halaman persetujuan, pernyataan orisinalitas, kata pengantar, daftar isi, daftar tabel, daftar gambar, daftar lampiran, abstrak, BAB 1,D-.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (930kB) | Preview |
![]() |
Text
D. RAMA_13201_10011181520069_00211117801_02-converted.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (421kB) | Request a copy |
![]() |
Text
E. RAMA_13201_10011181520069_00211117801_03-converted.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (126kB) | Request a copy |
![]() |
Text
F. RAMA_13201_10011181520069_00211117801_04-converted.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (303kB) | Request a copy |
![]() |
Text
G. RAMA_13201_10011181520069_00211117801_05-converted.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (301kB) | Request a copy |
![]() |
Text
H. RAMA_13201_10011181520069_00211117801_06-converted.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (140kB) | Request a copy |
![]() |
Text
I. RAMA_13201_10011181520069_00211117801_07-converted.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (36kB) | Request a copy |
![]() |
Text
J. RAMA_13201_10011181520069_00211117801_08_Referensidaftar pustaka-converted.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (81kB) | Request a copy |
![]() |
Text
K. RAMA_13201_10011181520069_00211117801_09_Lampiran-converted.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (417kB) | Request a copy |
Abstract
Dust is one of the results of an industrial process that can have a negative impact on the environment. Urea dust is dust coming from the urea granulation tower (prilling tower) that comes out from the chimney of each factory and has a size of 0.1-1000 millimicrons. The urea personal dust levels of NAB of more than 3 mg / m³ are found in the PPU 3 & 4 area. Personal dust is the level of dust that is inhaled due to individual exposure by attaching a tool on the worker's clothes during normal activities. Small enough dust particles remain in the inhaled air through the nose or mouth then settle in the lungs, causing a decrease in the vital capacity of a person's lung (3,500 ml). The proportion of lung vital capacity is 60.9%. This study aims to determine the personal dust levels with vital lung capacity factors of workers in the area of storage and storage of urea fertilizers 3 & 4. This study used a Cross Sectional design with a sample of workers of 110 people using the chi-square test. Analysis related to vital lung capacity is a factor of dust levels (p-value = 0.043); age (p-value = 0.041); smoking habits (p-value = 0.009); habit of using PPE (p-value = 0.032); duration of exposure (p-value = 0.028); working period (p-value = 0.017) and variables not related to lung vital capacity are factors from disease history and nutritional status. It can be concluded that work environment factors, and individuals have a relationship with vital lung capacity. The suggestion in this study is to make a local exhauster to reduce the level of dust found in the work environment.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Vital Lung Capacity, Personal Dust, Fertilizer |
Subjects: | K Law > K Law (General) > K3566-3578 Public health K Law > KB Religious law in general. Comparative religious law. Jurisprudence > KB3075-3096.5 Public health R Medicine > RA Public aspects of medicine > RA565-600 Environmental health. Including sewage disposal, air pollution, nuisances, |
Divisions: | 10-Faculty of Public Health > 13201-Public Health (S1) |
Depositing User: | Users 1200 not found. |
Date Deposited: | 09 Aug 2019 05:23 |
Last Modified: | 09 Aug 2019 05:23 |
URI: | http://repository.unsri.ac.id/id/eprint/2991 |
Actions (login required)
![]() |
View Item |