MULTAZAM, MUHAMMAD AGUNG and Fachrurrozi, Muhammad and Arsalan, Osvari (2020) PERBANDINGAN METODE INTERPOLASI BICUBIC DAN GABUNGAN METODE INTERPOLASI BICUBIC DENGAN DUAL TREE COMPLEX WAVELET TRANSFORM PADA PENINGKATAN KUALITAS CITRA MEDIS. Undergraduate thesis, Sriwijaya University.
Text
RAMA_55201_09021181320018.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (5MB) |
|
Text
RAMA_55201_09021181320018_TURNITIN.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (20MB) |
|
Preview |
Text
RAMA_55201_09021181320018_0222058001_0028068806_01_front_ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (1MB) | Preview |
Text
RAMA_55201_09021181320018_0222058001_0028068806_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (667kB) |
|
Text
RAMA_55201_09021181320018_0222058001_0028068806_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) |
|
Text
RAMA_55201_09021181320018_0222058001_0028068806_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) |
|
Text
RAMA_55201_09021181320018_0222058001_0028068806_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (505kB) |
|
Text
RAMA_55201_09021181320018_0222058001_0028068806_06.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (87kB) |
|
Text
RAMA_55201_09021181320018_0222058001_0028068806_06_ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (90kB) |
|
Text
RAMA_55201_09021181320018_0222058001_0028068806_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) |
Abstract
MRI (Magnetic Resonance Imaging) images can be used to help doctors or radiographers to analyze defects or provide an accurate diagnosis of a disease but the resulting MRI images have low resolution and still contain noise. Noise in the image can cause errors when a doctor or radiographer makes a diagnosis of the disease. In this study, MRI images quality enhancement software will be developed by comparing the performance of Bicubic Interpolation method for image enlargement and Dual Tree Complex Wavelet Transform method to improve the quality of the magnified image, and a combination of the two methods.The data used in this study were 200 MRI images, and the performance of both methods was calculated based on the PSNR value. Based on the results of the tests conducted, it is known that the combination of Bicubic Interpolation and DTCWT produces a better PSNR averagevalue of 32.323 (dB).
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | MRI image, Bicubic Interpolation, DTCWT |
Subjects: | Q Science > Q Science (General) > Q300-390 Cybernetics > Q325.5 Machine learning Q Science > Q Science (General) > Q334-342 Computer science. Artificial intelligence. Algorithms. Robotics. Automation. |
Divisions: | 09-Faculty of Computer Science > 55201-Informatics (S1) |
Depositing User: | Users 8033 not found. |
Date Deposited: | 21 Sep 2020 05:42 |
Last Modified: | 21 Sep 2020 05:42 |
URI: | http://repository.unsri.ac.id/id/eprint/35318 |
Actions (login required)
View Item |