ANALISIS GANGGUAN SISTEM TRANSMISI MENGGUNAKAN ALAT DIGITAL FAULT RECORDER DAN MENENTUKAN TITIK LOKASI GANGGUAN MELALUI PERBANDINGAN ALAT PELACAK BERBASIS TRAVELLING WAVE SYSTEM

SAPUTRA, CANRA ANDI and Zaini, Syamsuri (2020) ANALISIS GANGGUAN SISTEM TRANSMISI MENGGUNAKAN ALAT DIGITAL FAULT RECORDER DAN MENENTUKAN TITIK LOKASI GANGGUAN MELALUI PERBANDINGAN ALAT PELACAK BERBASIS TRAVELLING WAVE SYSTEM. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_20201_03041381621064.pdf] Text
RAMA_20201_03041381621064.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (11MB) | Request a copy
[thumbnail of RAMA_20201_03041381621064_TURNITIN.pdf] Text
RAMA_20201_03041381621064_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (22MB) | Request a copy
[thumbnail of RAMA_20201_03041381621064_0004035804_01_front_ref.pdf]
Preview
Text
RAMA_20201_03041381621064_0004035804_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (714kB) | Preview
[thumbnail of RAMA_20201_03041381621064_0004035804_02.pdf] Text
RAMA_20201_03041381621064_0004035804_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy
[thumbnail of RAMA_20201_03041381621064_0004035804_03.pdf] Text
RAMA_20201_03041381621064_0004035804_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy
[thumbnail of RAMA_20201_03041381621064_0004035804_04.pdf] Text
RAMA_20201_03041381621064_0004035804_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (565kB) | Request a copy
[thumbnail of RAMA_20201_03041381621064_0004035804_05.pdf] Text
RAMA_20201_03041381621064_0004035804_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (259kB) | Request a copy
[thumbnail of RAMA_20201_03041381621064_0004035804_06_ref.pdf] Text
RAMA_20201_03041381621064_0004035804_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (299kB) | Request a copy
[thumbnail of RAMA_20201_03041381621064_0004035804_07_lamp.pdf] Text
RAMA_20201_03041381621064_0004035804_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (7MB) | Request a copy

Abstract

DFR (Digital Fault Recorder) and TWS (Traveling Wave System) equipment which functions to record and store the data system condition automatically before, at the time of the disturbance and at the time after the disturbance, both in the form of disturbance type data and disturbance distance. This study uses the results of the recorded data on the DFR equipment which will be analyzed with the results of determining the characteristics of the disturbance that occurs by using the fault signature method and determining the location of the disturbance with the recorded data then it will be compared with the results of the recording on the TWS equipment. During the analysis process, the reseacher looked at the notes in the form of I Faul) and V Fault for each disturbance with data obtained within a period of 8 months starting from January 14 to August 12 2020. Furthermore, I Fault and V Fault will be taken as input in formula processing. With the result obtained that there were 8 disturbance caused by lightning, 1 disturbance caused by tree/ground, and 1 disturbance caused by dirty isolator and difference between the two rasio ± 0,5 KM with between difference 0,07 – 0,5 KM. The result obtained that there were from 6 disturbance immediately checked in the field have 4 disturbance approaching from manual calculation used record file DFR Equipment and 2 other disturbance approaching with record file from TWS equipment. So in terms of accuracy and optimalization, manual calculation very effective for used.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: DFR, TWS, Karakteristik Gangguan, Lokasi Gangguan
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3001-3521 Distribution or transmission of electric power
Divisions: 03-Faculty of Engineering > 20201-Electrical Engineering (S1)
Depositing User: Users 4078 not found.
Date Deposited: 13 Jan 2021 02:46
Last Modified: 13 Jan 2021 02:46
URI: http://repository.unsri.ac.id/id/eprint/39864

Actions (login required)