ASLAMIA, HERTIA and Untari, Budi and Fithri, Najma Annuria (2018) STUDI PERBANDINGAN METODE UJI DISOLUSI SEDIAAN SNEDDS ASAM MEFENAMAT MENGGUNAKAN APARATUS TIPE II DAN METODE BEKER DENGAN GLASS BEADS. Undergraduate thesis, Sriwijaya University.
Preview |
Text
RAMA_48201_08061181419097_00102658002_01_front_ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (1MB) | Preview |
Text
RAMA_48201_08061181419097_00102658002_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (711kB) | Request a copy |
|
Text
RAMA_48201_08061181419097_00102658002_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (289kB) | Request a copy |
|
Text
RAMA_48201_08061181419097_00102658002_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (453kB) | Request a copy |
|
Text
RAMA_48201_08061181419097_00102658002_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (11kB) | Request a copy |
|
Text
RAMA_48201_08061181419097_00102658002_06_ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (265kB) | Request a copy |
|
Text
RAMA_48201_08061181419097_00102658002_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (325kB) | Request a copy |
Abstract
A comparative study about dissolution profiles of mefenamic acid SNEDDS tested by the method of type II apparatus and beker method with glass beads has been done. This study aimed to determine the similarity between the method of type II apparatus and alternative method using a beaker with glass beads. This comparison study began by validating the analytical method and then comparing two dissolution test methods through the values of difference factor (f1) and similarity factor (f2) and also by statistical comparison. The results showed that this analytical method validation was accurate and precise because the parameter values were well within the limits (% recovery of 100.784%,% RSD of 0.333%, and R value of 0.9998) with LOD of 0.4433 ppm and LOQ of 1.4777 ppm. Mefenamic acid SNEDDS tested by type II apparatus and also by beaker method with glass beads were resulting similar dissolution profiles with difference factor (f1) of 4.6794 and similarity factor (f2) of 71.2002 (f1<15 and f2>50). Dissolution rate of mefenamic acid SNEDDS tested by the method of type II apparatus and beaker method with glass beads has reached release > 100% after 10 minutes of dissolution and followed Weibull release model with super case II transport release mechanism. Statistical analysis indicated that there was no significant difference in % release and % DE of the dosage forms tested by type II apparatus compared to the dosage forms tested by beaker method with glass beads (p>0.05). These results indicated that the alternative method of beaker with glass beads is able to give similar dissolution profile compared to the method of type II apparatus.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | SNEDDS, mefenamic acid, dissolution, type II apparatus method, beaker method with glass beads |
Subjects: | R Medicine > RS Pharmacy and materia medica > RS192-199 Pharmaceutical technology R Medicine > RS Pharmacy and materia medica > RS400-431 Pharmaceutical chemistry |
Divisions: | 08-Faculty of Mathematics and Natural Science > 48201-Pharmacy (S1) |
Depositing User: | Mrs Dies Meirita Sari |
Date Deposited: | 16 Aug 2019 08:22 |
Last Modified: | 16 Aug 2019 08:22 |
URI: | http://repository.unsri.ac.id/id/eprint/4479 |
Actions (login required)
View Item |