KAJIAN TEKNIS SISTEM VENTILASI TAMBANG UNTUK KEBUTUHAN OPERASIONAL PENAMBANGAN PADA TAMBANG BATUBARA BAWAH TANAH PT. KUSUMA RAYA UTAMA, KABUPATEN BENGKULU TENGAH, PROVINSI BENGKULU

HIFRIANSYAH, MUHAMMAD GIFFARY and Purbasari, Diana and Komar, Syamsul (2021) KAJIAN TEKNIS SISTEM VENTILASI TAMBANG UNTUK KEBUTUHAN OPERASIONAL PENAMBANGAN PADA TAMBANG BATUBARA BAWAH TANAH PT. KUSUMA RAYA UTAMA, KABUPATEN BENGKULU TENGAH, PROVINSI BENGKULU. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_31201_03021381722086.pdf] Text
RAMA_31201_03021381722086.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (4MB) | Request a copy
[thumbnail of RAMA_31201_03021381722086_TURNITIN.pdf] Text
RAMA_31201_03021381722086_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (11MB) | Request a copy
[thumbnail of RAMA_31201_03021381722086_ 0017048203_ 0010125201_01_front_ref.pdf]
Preview
Text
RAMA_31201_03021381722086_ 0017048203_ 0010125201_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Preview
[thumbnail of RAMA_31201_03021381722086_ 0017048203_ 0010125201_02.pdf] Text
RAMA_31201_03021381722086_ 0017048203_ 0010125201_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (913kB) | Request a copy
[thumbnail of RAMA_31201_03021381722086_ 0017048203_ 0010125201_03.pdf] Text
RAMA_31201_03021381722086_ 0017048203_ 0010125201_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (327kB) | Request a copy
[thumbnail of RAMA_31201_03021381722086_ 0017048203_ 0010125201_04.pdf] Text
RAMA_31201_03021381722086_ 0017048203_ 0010125201_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy
[thumbnail of RAMA_31201_03021381722086_ 0017048203_ 0010125201_05.pdf] Text
RAMA_31201_03021381722086_ 0017048203_ 0010125201_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (161kB) | Request a copy
[thumbnail of RAMA_31201_03021381722086_ 0017048203_ 0010125201_06_ref.pdf] Text
RAMA_31201_03021381722086_ 0017048203_ 0010125201_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (185kB) | Request a copy
[thumbnail of RAMA_31201_03021381722086_ 0017048203_ 0010125201_07_lamp.pdf] Text
RAMA_31201_03021381722086_ 0017048203_ 0010125201_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy

Abstract

Mine ventilation is an effort to control the movement of air. In order to obtain detailed information regarding the quantity, quality, and propulsion of air required for underground mining operations in the ventilation network system, it is necessary to conduct a technical study of the existing ventilation system. The minimum amount of air required for the operational needs of the Seluang underground mine PT. Kusuma Raya Utama is as much as 45.16 m3/s based on the minimum air requirement for breathing per person, equipment requirements, and gas dilution according to the Decree of the Director General of Mineral and Coal No.185.K/3.04/DJB/2019. The amount of clean air supply that enters the Seluang mine is 55.54 m3/s. So that the air supply in the Seluang mine meets the required minimum air requirements. The methane gas content 0.007% and 0.0002% CO gas is still below the threshold for the maximum volume of methane and CO 0.25% for methane and 0.005% for CO. The measurement location 15 shows a value higher than the allowable air temperature limit, which is 18oC to 27oC, while the humidity in the mine is 86% to 92% which generally exceeds the permissible threshold of 85%. Measurement of air propulsion required to overcome resistance or decrease in ventilation pressure at the Seluang Mine is 127.72 Kw. Keywords : Ventilation, Quantity, Quality, Air Power

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Ventilasi, Kuantitas, Kualitas, Daya Penggerak Udara
Subjects: T Technology > TN Mining engineering. Metallurgy > TN1-997 Mining engineering. Metallurgy
Divisions: 03-Faculty of Engineering > 31201-Mining Engineering (S1)
Depositing User: Mr. Muhammad Giffary Hifriansyah
Date Deposited: 12 Jul 2021 07:33
Last Modified: 12 Jul 2021 07:33
URI: http://repository.unsri.ac.id/id/eprint/49715

Actions (login required)

View Item View Item