KAJI EKSPERIMENTAL PERFORMANSI AIR CONDITIONING SPLIT UNTUK REFRIGERAN R-410-A DAN R-22

DUSYADI, DUSYADI and Astuti, Astuti and Bizzy, Irwin (2017) KAJI EKSPERIMENTAL PERFORMANSI AIR CONDITIONING SPLIT UNTUK REFRIGERAN R-410-A DAN R-22. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_21201_03051381320037_0008107204 _0028086015_01_front_ref.pdf]
Preview
Text
RAMA_21201_03051381320037_0008107204 _0028086015_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (479kB) | Preview
[thumbnail of RAMA_21201_03051381320037_0008107204 _0028086015_02.pdf] Text
RAMA_21201_03051381320037_0008107204 _0028086015_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (447kB) | Request a copy
[thumbnail of RAMA_21201_03051381320037_0008107204 _0028086015_03.pdf] Text
RAMA_21201_03051381320037_0008107204 _0028086015_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (276kB) | Request a copy
[thumbnail of RAMA_21201_03051381320037_0008107204 _0028086015_04.pdf] Text
RAMA_21201_03051381320037_0008107204 _0028086015_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy
[thumbnail of RAMA_21201_03051381320037_0008107204 _0028086015_05.pdf] Text
RAMA_21201_03051381320037_0008107204 _0028086015_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (91kB) | Request a copy
[thumbnail of RAMA_21201_03051381320037_0008107204 _0028086015_06_ref.pdf] Text
RAMA_21201_03051381320037_0008107204 _0028086015_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (170kB) | Request a copy
[thumbnail of RAMA_21201_03051381320037_0008107204 _0028086015_07_lamp.pdf] Text
RAMA_21201_03051381320037_0008107204 _0028086015_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (512kB) | Request a copy

Abstract

The purpose of this research is to analyze the performance of Air Conditioning (AC) with power 1 PK, to know the effect of COP (Coefficient of performance) with variation of regulator valve opening. The data obtained during the test air conditioner use some measuring equipment, such as Thermometer, Presseur gauge, refrigerant (digital), Manifold gauge, Vacuum pump, Leak Detector, Compressor. The result of COP pressure data on the influence of valve opening, From the calculation of COP with R-410-A refrigerant, the opening speed of the regulator valve 1/4 value is 5.11, the valve opening 2/4 value is 5.89, the valve opening 3/4 value is 7 , 43, 4/4 valve opening value 10.09. For the calculation of R22 refrigerant with the opening valve 1/4 value 4.55, valve openings 2/4 value 5.1, valve opening 3/4 value 6.45, 4/4 valve opening value 7.33. From the calculation of COP on refrigerant R-410-A higher in comparison with COP refrigerant R-22. From this it shows that R-410-A refrigerant consumes a low energy in comparison with R-22 refrigerant for the same cooling power absorption for desired.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Air conditioning split,Refrigerant, Regulating Valve, COP,
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ1-1570 Mechanical engineering and machinery
Divisions: 03-Faculty of Engineering > 21201-Mechanical Engineering (S1)
Depositing User: Mrs Kharisma Afrianti
Date Deposited: 05 Sep 2019 16:45
Last Modified: 05 Sep 2019 16:45
URI: http://repository.unsri.ac.id/id/eprint/6444

Actions (login required)

View Item View Item