RAFQI, BRE GIUSTI AFIF and Bizzy, Irwin (2023) RANCANG BANGUN DISPENSER MINI MENGGUNAKAN THERMOELECTRIC COOLER TEC1-12705. Undergraduate thesis, Sriwijaya University.
Text
RAMA_21201_03051381924116.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (3MB) | Request a copy |
|
Text
RAMA_21201_03051381924116_TURNITIN.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) | Request a copy |
|
Preview |
Text
RAMA_21201_03051381924116_0028086015_01_front_ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (751kB) | Preview |
Text
RAMA_21201_03051381924116_0028086015_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (559kB) | Request a copy |
|
Text
RAMA_21201_03051381924116_0028086015_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (472kB) | Request a copy |
|
Text
RAMA_21201_03051381924116_0028086015_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (514kB) | Request a copy |
|
Text
RAMA_21201_03051381924116_0028086015_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (122kB) | Request a copy |
|
Text
RAMA_21201_03051381924116_0028086015_06_ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (72kB) | Request a copy |
|
Text
RAMA_21201_03051381924116_0028086015_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (602kB) | Request a copy |
Abstract
The design of this mini dispenser aims to reduce the use of conventional dispenser components, which use heating elements and refrigerants and determine the performance of the TEC1-12705 module. And data logger as data retrieval automation. Based on data obtained from data loggers and thermocouples, cold water temperatures can reach 24.4℃, and hot water can reach temperatures of 38.1℃. The temperature generated by the TEC on the hot side reaches 61.4 ℃, while on the cold side, it reaches 24.8 ℃. While for the valve opening ½, the temperature of the hot side TEC can produce 60.4 ℃, and the cold side TEC 31.3 ℃. For hot water at ½ valve opening is 44.9 ℃, and cold water can reach 34.3 ℃
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Dispenser,TEC,TEC1-12705 |
Subjects: | T Technology > TJ Mechanical engineering and machinery > TJ255-265 Heat engines > TJ263.T493 Heat exchangers--Congresses. Steam-boilers--Congresses. Fluid dynamics--Congresses. Heat--Transmission--Congresses |
Divisions: | 03-Faculty of Engineering > 21201-Mechanical Engineering (S1) |
Depositing User: | Bre Giusti Afif Rafqi |
Date Deposited: | 30 Jan 2023 06:45 |
Last Modified: | 30 Jan 2023 06:45 |
URI: | http://repository.unsri.ac.id/id/eprint/88462 |
Actions (login required)
View Item |