AHMADIRIZKA, IRHAM and Hikmarika, Hera (2018) IMPLEMENTASI LOGIKA FUZZY DALAM KENDALI MESIN PENDINGIN RUANGAN. Undergraduate thesis, Sriwijaya University.
Preview |
Text
RAMA_20201_03041381419112_0007127801_01_front_ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (394kB) | Preview |
Text
RAMA_20201_03041381419112_0007127801_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (274kB) | Request a copy |
|
Text
RAMA_20201_03041381419112_0007127801_03.pdf - Accepted Version Restricted to Repository staff only Download (38kB) | Request a copy |
|
Text
RAMA_20201_03041381419112_0007127801_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (411kB) | Request a copy |
|
Text
RAMA_20201_03041381419112_0007127801_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (21kB) | Request a copy |
|
Text
RAMA_20201_03041381419112_0007127801_06.ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (19kB) | Request a copy |
|
Text
RAMA_20201_03041381419112_0007127801_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (211kB) | Request a copy |
Abstract
Air Conditioner (AC) has the mainfunction of conditioning the air to create more comfortable atmosphere in the rootn.The energt usoge oJ'air conditioner is very large, One way that can help to improte fficiency is to regulctte the temperature of air conditioner so as to get the optimal temperature in a room. The temperature of air conditianer can be adjusted according to the {tmount of movernent intensity in a raom. So when there is a significant movement, the temperature on the air conditioner will go down and rise u,hen it does not detect qny movement. To get the optimal temperature of a room, we can use Fuzzy Sugeno calculalion method. Human mavement intensity and detected room temperature will be the input variables in Fuzzy Sugeno method. By experimenting on the PIR sensor to detect the intensity of human movement and DHTI I sensor to detect the room tempernture, we con determine the input range for the Fuzzy method ,u,hich then after fuzzification process the optimal temperature of the room can be obtained. Fuzzy calculation can be done in Arduino code so that the optimum temperatw'e can be directly implemented on the air conditioner.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Air Conditioner, Fuzzy Sugeno, fuzzifikasi, PIR sensor, DHTI I sensor, Arduino. |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK1-9971 Electrical engineering. Electronics. Nuclear engineering > TK1 Electrical engineering--Periodicals. Automatic control--Periodicals. Computer science--Periodicals. Information technology--Periodicals. Automatic control. Computer science. Electrical engineering. Information technology. |