SADILA, YUNIRA and Costa, Anthony (2024) ANALISA KEKUATAN BALOK DAN KOLOM PROFIL BAJA MENGGUNAKAN METODE ANALISIS PUSHOVER(STUDI KASUS BANGUNAN INTAKE POMPA KARANGANYAR, PULOKERTO). Undergraduate thesis, Sriwijaya University.
Text
RAMA_22201_03011182025017.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (10MB) |
|
Text
RAMA_22201_03011182025017_TURNITIN.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (4MB) | Request a copy |
|
Text
RAMA_22201_03011182025017_0022079003_01_front_ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (5MB) |
|
Text
RAMA_22201_03011182025017_0022079003_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (2MB) | Request a copy |
|
Text
RAMA_22201_03011182025017_0022079003_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (2MB) | Request a copy |
|
Text
RAMA_22201_03011182025017_0022079003_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (3MB) | Request a copy |
|
Text
RAMA_22201_03011182025017_0022079003_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (225kB) | Request a copy |
|
Text
RAMA_22201_03011182025017_0022079003_06_ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (530kB) | Request a copy |
|
Text
RAMA_22201_03011182025017_0022079003_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (4MB) | Request a copy |
Abstract
The intake structure is a building that functions as a place to take water from the river and drain it to the processing site. In the research conducted for regulations using provisions that refer to SNI 1726:2019, ASCE 41-17, and FEMA 356:2000 regarding pushover analysis. Non-linear Static Analysis or better known as Pushover Analysis is a method used to analyze the capacity curve of the relationship between the base shear force and the displacement of the reference point, as well as obtaining the location of plastic hinges in the steel beam-column structure, so as to obtain the collapse behavior of the intake building structure. Based on the results of the analysis of the ETABS assistance program, a displacement of 0,176055 m is obtained, resulting in a base shear force of 90938,8568 kN and 44460,7884 kN for each X direction and Y direction, and the structural performance level is immediate occupancy and life safety. Meanwhile, based on FEMA 356, a displacement of 4,3087 x 10^(-3) m and 6,2214 x 10^(-3) m is obtained in each X direction and Y direction, respectively, whose condition is Immediate Occupancy because the actual drift is less than 1%.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Intake Structure, Steel Beam-Column, ETABS, Pushover Analysis |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) > TA174 Engineering design T Technology > TH Building construction |
Divisions: | 03-Faculty of Engineering > 22201-Civil Engineering (S1) |
Depositing User: | Yunira Sadila |
Date Deposited: | 20 Mar 2024 01:45 |
Last Modified: | 20 Mar 2024 01:45 |
URI: | http://repository.unsri.ac.id/id/eprint/141862 |
Actions (login required)
View Item |