PENGARUH VARIASI KETEBALAN ISOLATOR TERHADAP LAJU KALOR DAN PENURUNAN TEMPERATUR PADA PERMUKAAN TUNGKU BIOMASSA

KHOIRULLAH, MUHAMMAD INDAKA and Thamrin, Ismail (2014) PENGARUH VARIASI KETEBALAN ISOLATOR TERHADAP LAJU KALOR DAN PENURUNAN TEMPERATUR PADA PERMUKAAN TUNGKU BIOMASSA. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_21201_03071005079.pdf] Text
RAMA_21201_03071005079.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (98MB) | Request a copy
[thumbnail of RAMA_21201_03071005079_0002097104_01_front_ref.pdf] Text
RAMA_21201_03071005079_0002097104_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (19MB)
[thumbnail of RAMA_21201_03071005079_0002097104_02.pdf] Text
RAMA_21201_03071005079_0002097104_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (12MB) | Request a copy
[thumbnail of RAMA_21201_03071005079_0002097104_03.pdf] Text
RAMA_21201_03071005079_0002097104_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (6MB) | Request a copy
[thumbnail of RAMA_21201_03071005079_0002097104_04.pdf] Text
RAMA_21201_03071005079_0002097104_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (15MB) | Request a copy
[thumbnail of RAMA_21201_03071005079_0002097104_05.pdf] Text
RAMA_21201_03071005079_0002097104_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (899kB) | Request a copy
[thumbnail of RAMA_21201_03071005079_0002097104_06_ref.pdf] Text
RAMA_21201_03071005079_0002097104_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (830kB) | Request a copy
[thumbnail of RAMA_21201_03071005079_0002097104_07_lamp.pdf] Text
RAMA_21201_03071005079_0002097104_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (43MB) | Request a copy

Abstract

Heat exchanger is a device used to heat exchanger fluid from a fluid to another through a solid surface due to the temperature difference. The process of heat transfer can be done directly and indirectly. Direct heat exchanger, is a fluid that has a higher temperature (heat) will be mixed directly with a fluid that has a lower temperature (cold) in a vessel or room. Meanwhile, heat exchanger indirect, is not related to the hot fluid to cold fluid directly but through an intermediary in the form of solid media. Each surface has a higher temperature (hotter) than the surrounding temperature will experience the heat release (heat loss), thereby increasing the environmental temperature becomes higher. The amount of heat loss depends on many factors, but the surface temperature and its size is the dominant factor. To reduce the heat transfer is used thermal insulator. By providing an insulating layer (insulation) on a hot surface will reduce overall surface temperature. This study aims to determine how much influence the thickness of the insulator against heat rate and a decrease in temperature at the surface of the biomass fumace using plywood insulator with a thickness of 3 mm, 6 mm and 9 mm.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: A heat exchanger, heat rate, heat loss, Insulation, Fumace biomass
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ1-1570 Mechanical engineering and machinery
Divisions: 03-Faculty of Engineering > 21201-Mechanical Engineering (S1)
Depositing User: Mrs Furika Furika
Date Deposited: 27 Sep 2024 03:47
Last Modified: 27 Sep 2024 03:47
URI: http://repository.unsri.ac.id/id/eprint/158141

Actions (login required)

View Item View Item