PERBANDINGAN KEKUATAN TEKAN GLASS IONOMER CEMENT (FUJI IX) DENGAN CERAMIC REINFORCED GLASS IONOMER (AMALGOMER CR)

APRIANI, ANGGI and MERDEKAWATI, LISTIA EKA and Sujatmiko, Billy (2025) PERBANDINGAN KEKUATAN TEKAN GLASS IONOMER CEMENT (FUJI IX) DENGAN CERAMIC REINFORCED GLASS IONOMER (AMALGOMER CR). Undergraduate thesis, Sriwijaya Universiti.

[thumbnail of RAMA_12201_04031281823037_cover.jpg] Text
RAMA_12201_04031281823037_cover.jpg - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (1MB)
[thumbnail of RAMA_12201_04031281823037.pdf] Text
RAMA_12201_04031281823037.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (35MB) | Request a copy
[thumbnail of RAMA_12201_04031281823037_TURNITIN.pdf] Text
RAMA_12201_04031281823037_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (6MB) | Request a copy
[thumbnail of RAMA_12201_04031281823037_0031018401_8880150017_01_front_ref.pdf] Text
RAMA_12201_04031281823037_0031018401_8880150017_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (37MB)
[thumbnail of RAMA_12201_04031281823037_0031018401_8880150017_02.pdf] Text
RAMA_12201_04031281823037_0031018401_8880150017_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (208kB) | Request a copy
[thumbnail of RAMA_12201_04031281823037_0031018401_8880150017_03.pdf] Text
RAMA_12201_04031281823037_0031018401_8880150017_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (424kB) | Request a copy
[thumbnail of RAMA_12201_04031281823037_0031018401_8880150017_04.pdf] Text
RAMA_12201_04031281823037_0031018401_8880150017_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Request a copy
[thumbnail of RAMA_12201_04031281823037_0031018401_8880150017_05.pdf] Text
RAMA_12201_04031281823037_0031018401_8880150017_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (82kB) | Request a copy
[thumbnail of RAMA_12201_04031281823037_0031018401_8880150017_06_ref.pdf] Text
RAMA_12201_04031281823037_0031018401_8880150017_06_ref.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (128kB) | Request a copy
[thumbnail of RAMA_12201_04031281823037_0031018401_8880150017_07_lamp.pdf] Text
RAMA_12201_04031281823037_0031018401_8880150017_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (14MB) | Request a copy

Abstract

Latar Belakang: Glass Ionomer Cement (GIC) adalah salah satu bahan restorasi untuk mengembalikan fungsi dari gigi dengan cara melekat pada enamel serta dentin melalui suatu ikatan kimia asam basa antara bubuk kaca aluminolisikat dan asam poliakrilat. Amalgomer CR dan GIC FUJI IX sama-sama diindikasikan untuk restorasi posterior yang memerlukan kekuatan tekan saat penguyahan Penelitian ini bertujuan untuk mengetahui perbedaan kekuatan tekan Amalgomer CR dengan GIC FUJI IX. Tujuan: Membandingkan kekuatan tekan Amalgomer CR dengan GIC FUJI IX. Metode: Jenis Penelitian eksperimental dengan penelitian post-test only design group. GIC dibagi menjadi 2 kelompok yaitu Amalgomer CR dan GIC FUJI IX yang masing-masing berjumlah 16 sampel. Sampel dilakukan pengujian kekuatan tekan dengan alat universal testing machine. Data yang diperoleh dilakukan uji statistik saphiro-wilk dan t-tes Independent. Hasil: Kekuatan tekan Amalgomer CR dengan GIC FUJI IX terdapat perbedaan nilai kekuatan tekan yang signifikan. Kesimpulan: Kekuatan tekan Amalgomer CR lebih tinggi dibandingkan dengan bahan GIC FUJI IX. Hal tersebut dibuktikan dengan nilai rata-rata kekuatan tekan pada Ceramic reinforced glass ionomer (Amalgomer CR) yaitu 31,21 MPa, sedangkan kekuatan tekan pada Glass Ionomer Cement (Fuji IX) yaitu 21,60 MPa. Kata Kunci: Amalgomer CR,GIC FUJI IX, kekuatan tekan.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Amalgomer CR,GIC FUJI IX, kekuatan tekan.
Subjects: R Medicine > RK Dentistry > RK501-519 Operative dentistry. Restorative dentistry
Divisions: 04-Faculty of Medicine > 12201-Dentistry (S1)
Depositing User: Anggi Apriani
Date Deposited: 26 Jul 2025 15:57
Last Modified: 26 Jul 2025 15:57
URI: http://repository.unsri.ac.id/id/eprint/180808

Actions (login required)

View Item View Item