Saloma, Saloma and YAKNI, BILAL and Hanafiah, Hanafiah and NICO, MUHAMMAD OKTA (2017) Structural Behaviour of Steel Building with Diagonal and Chevron Braced CBF (Concentrically Braced Frames) by Pushover Analysis. International Journal on Advanced Science, Engineering and Information Technology, 7 (2). pp. 716-722. ISSN 2088-5334
Preview |
Text
ALLPAPER JURNAL INTERNASIONAL 2 HANAFIAH UPLOAD.pdf Download (1MB) | Preview |
Abstract
This paper presents diagonal and chevron braced steel structure design with pushover analysis conducted following ATC-40 guidelines. In this study, the lateral load used is increased gradually until plastic hinge and collapse occur. The results are capacity curve, performance point, and the process of plastic hinge until the building collapse. There are five steel structure models designed based on the various types of bracing and bracing configuration. Model 1 is steel structure without bracing, model 2 and 3 are chevron braced steel structure, model 4 and 5 are diagonal braced steel structure. The results of this study indicate that the performance level of five models structure for earthquake in x direction and y direction according to ATC-40 is IO (Immediate Occupancy). Model 4 has the best effectiveness in terms of plastic hinge mechanism compared to other models. In the last step, model 4 is able to reduce plastic hinge 84% from model 1 for earthquake in x direction and 79% from model 1 for earthquake in y direction. Model 3 has the greatest ability to carry the forces of an earthquake compared to other models. It is 185% bigger than model 1 for x direction and 181% bigger than model 1for y direction. Model 3 has the greatest effectiveness in reducing lateral displacements compared to other models in the amount of 65.47% of model 1 for x direction and 72.14% of model 1 for y direction. Model 3 has the greatest effectiveness in reducing storey drift compared to other models in the amount of 73.89% of model 1 for x direction and 80.55% of model 1 for y direction. Keywords: pushover analysis; capacity curve; performance point; immediate occupancy
Item Type: | Article |
---|---|
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) > TA1-2040 Engineering (General). Civil engineering (General) > TA169.H37 Reliability (Engineering), Engineering design, Civil engineering |
Divisions: | 03-Faculty of Engineering > 22201-Civil Engineering (S1) |
Depositing User: | Hanafiah Hanafiah |
Date Deposited: | 29 May 2020 03:27 |
Last Modified: | 29 May 2020 03:27 |
URI: | http://repository.unsri.ac.id/id/eprint/29435 |
Available Versions of this Item
- Structural Behaviour of Steel Building with Diagonal and Chevron Braced CBF (Concentrically Braced Frames) by Pushover Analysis. (deposited 29 May 2020 03:27) [Currently Displayed]
Actions (login required)
View Item |